1 |
ron |
1 |
These are example configurations for the low-cost [Acrylic Prusa I3 pro B 3D Printer DIY kit](http://www.geeetech.com/acrylic-geeetech-prusa-i3-pro-b-3d-printer-diy-kit-p-917.html) and the [3DTouch auto bed leveling sensor](http://www.geeetech.com/geeetech-3dtouch-auto-bed-leveling-sensor-for-3d-printer-p-1010.html) based on:
|
|
|
2 |
|
|
|
3 |
- `../GT2560/`
|
|
|
4 |
- [Marlin 1.1.4 With 3DTouch / BLTouch for i3 Pro B](https://www.geeetech.com/forum/viewtopic.php?t=19846)
|
|
|
5 |
|
|
|
6 |
The main characteristics of these configurations are:
|
|
|
7 |
|
|
|
8 |
- The defined motherboard is `BOARD_GT2560_REV_A_PLUS`.
|
|
|
9 |
- Travel limits are adjusted to the printer bed size and position.
|
|
|
10 |
- An example `SKEW_CORRECTION` for a particular printer is enabled. See comments below about how to adjust it to a particular printer.
|
|
|
11 |
- Using the LCD controller for bed leveling is enabled.
|
|
|
12 |
- `PROBE_MANUALLY` is enabled, which *provides a means to do "Auto" Bed Leveling without a probe*.
|
|
|
13 |
- The `LEVEL_BED_CORNERS` option for manual bed adjustment is enabled.
|
|
|
14 |
- Bilinear bed leveling is enabled, the boundaries for probing are adjusted to the glass size, and extrapolation is enabled.
|
|
|
15 |
- `PRINTCOUNTER` is enabled, in order to track statistical data.
|
|
|
16 |
- `INDIVIDUAL_AXIS_HOMING_MENU` is enabled, which adds individual axis homing items (Home X, Home Y, and Home Z) to the LCD menu.
|
|
|
17 |
- The speaker is enabled for the UI feedback.
|
|
|
18 |
- `bltouch` variant:
|
|
|
19 |
- `USE_ZMAX_PLUG` is enabled. See comments about connections below.
|
|
|
20 |
- Heaters and fans are turned off when probing.
|
|
|
21 |
- Multiple probing is set to 3.
|
|
|
22 |
|
|
|
23 |
# First-time configuration
|
|
|
24 |
|
|
|
25 |
## Skew factor
|
|
|
26 |
|
|
|
27 |
The skew factor must be adjusted for each printer:
|
|
|
28 |
|
|
|
29 |
- First, uncomment `#define XY_SKEW_FACTOR 0.0`, compile and upload the firmware.
|
|
|
30 |
- Then, print [YACS (Yet Another Calibration Square)](https://www.thingiverse.com/thing:2563185). Hint, scale it considering a margin for brim (if used). The larger, the better to make error measurements.
|
|
|
31 |
- Measure the printed part according to the comments in the example configuration file, and set `XY_DIAG_AC`, `XY_DIAG_BD` and `Y_SIDE_AD`.
|
|
|
32 |
- Last, comment `#define XY_SKEW_FACTOR 0.0` again, compile and upload.
|
|
|
33 |
|
|
|
34 |
## 3DTouch auto leveling sensor
|
|
|
35 |
|
|
|
36 |
- Print a suitable mount to attach the sensor to the printer. The example configuration file is adjusted to http://www.geeetech.com/wiki/images/6/61/3DTouch_auto_leveling_sensor-1.zip
|
|
|
37 |
- Unlike suggested in [geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor](https://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor), the existing end stop switch is expected to be kept connected to Z_MIN. So, the sensor is to be connected to Z_MAX, according to Marlin's default settings. Furthermore, GT2560-A+ provides a connector for the servo next to thermistor connectors (see [GT2560](https://www.geeetech.com/wiki/images/thumb/4/45/GT2560_wiring.jpg/700px-GT2560_wiring.jpg) and [GT2560-A+](http://i.imgur.com/E0t34VU.png)).
|
|
|
38 |
- Be careful to respect the polarity of the sensor when connecting it to the GT2560-A+. Unlike end stops, reversing the connection will prevent the sensor from working properly.
|
|
|
39 |
- [Test](http://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor#Testing) and [calibrate](https://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor#Calibration) the sensor.
|